GP-4201TM/4301TM/4000M Hardware Manual
34
Interface Specifications
Serial Interface COM1
USB Interface
Ethernet Interface
NOTE: Ethernet networks must be installed by a trained and qualified person.
When connecting the external device directly to the GP unit with an Ethernet cable,
depending on the external device, communication may not be possible.
Please connect over a network hub.
The following table describes the LED colors and status:
Asynchronous Transmission RS232C / RS422 / RS485
Data Length 7 or 8 bits
Stop Bit 1 or 2 bits
Parity None, odd or even
Data Transmission Speed 2,400...115.200 kbps, 187,500 bps
Connector D-Sub 9 pin (plug)
Connector Power Supply
Voltage
Maximum
Current
Supplied
Maximum
Transmission
Distance
USB (Type A)
Interface
USB2.0 (Type
A) x 1
5Vdc
±5%
200mA 3 m (9.84 ft)
USB (mini-B)
Interface
USB2.0 (mini-
B) x 1
- - 5 m (16.40 ft)
Ethernet (LAN) IEEE802.3i/ IEEE802.3u, 10BASE-T/100BASE-TX
Connector Modular jack (RJ-45) x 1
LED Contents
Green lit Data transmission is available.
blinking Data transmission is occurring.